<?xml version="1.0"?>
<rss version="2.0">
   <channel>
      <title>Performance Objectives by Tom Heaney</title>
      <link>https://padlet.com/theaney/qiyb7j19tx70</link>
      <description>Construct a PO for one major step or subskill identified in your group&#39;s instructional analysis. Post it here.</description>
      <language>en-us</language>
      <pubDate>2016-06-19 15:48:43 UTC</pubDate>
      <lastBuildDate>2017-05-07 14:15:07 UTC</lastBuildDate>
      <webMaster>hello@padlet.com</webMaster>
      <image>
         <url></url>
      </image>
      <item>
         <title>David Turnipseed</title>
         <author></author>
         <link>https://padlet.com/theaney/qiyb7j19tx70/wish/169991713</link>
         <description><![CDATA[<div>Instructional Goal: Perform a maintenance check of an electric furnace and heat pump <br><br>Terminal Objective: Given an electric furnace and heat pump in need of a yearly service, all tools required to remove panels and perform maitenance organized in their normal positions in the tool bag [Condition], check the condition of the wires, switches, filters, and condensation system of the electric furnace and heat pump [Behavior]. Each step in the procedure will be performed in sequence and according to criteria specified for each step [Criteria]. </div>]]></description>
         <enclosure url="" />
         <pubDate>2017-05-04 16:39:41 UTC</pubDate>
         <guid>https://padlet.com/theaney/qiyb7j19tx70/wish/169991713</guid>
      </item>
      <item>
         <title>Aaron Tran</title>
         <author></author>
         <link>https://padlet.com/theaney/qiyb7j19tx70/wish/170287023</link>
         <description><![CDATA[<div>Instructional Goal: •Consult client on maintenance performed and future care of unit <br><br>Performance Objective:<br>Give a comprehensive overview of the steps completed in the maintenance, which includes answering any questions about present and future care for the unit.</div>]]></description>
         <enclosure url="" />
         <pubDate>2017-05-06 04:30:55 UTC</pubDate>
         <guid>https://padlet.com/theaney/qiyb7j19tx70/wish/170287023</guid>
      </item>
      <item>
         <title>Lori Kunkler</title>
         <author>kunklerl</author>
         <link>https://padlet.com/theaney/qiyb7j19tx70/wish/170362081</link>
         <description><![CDATA[<div>Instructional Goal:  Test pipe or tubing joints or connections for leaks, using pressure gauge or soap-and-water solution.<br><br>Performance Objective:  Given a gas furnace, required tools (including a pressure gauge, liquid soap, gas sniffer), check each pipe and tubing joint/connections for natural gas leaks.  All gas leaks must be found and reported to the instructor.  (100%)</div>]]></description>
         <enclosure url="" />
         <pubDate>2017-05-07 14:08:20 UTC</pubDate>
         <guid>https://padlet.com/theaney/qiyb7j19tx70/wish/170362081</guid>
      </item>
   </channel>