         <title>Instalaciones Eléctricas</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1515561999</link>
         <description><![CDATA[<div>ADA 7: Organizador Gráfico</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-11 23:25:26 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1515561999</guid>
      </item>
      <item>
         <title>Capitulo 1: Disposiciones generales</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521250662</link>
         <description><![CDATA[<div>&nbsp;El artículo <strong>100</strong> define una unidad de vivienda bifamiliar como un edificio que contiene dos unidades de vivienda</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 14:44:20 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521250662</guid>
      </item>
      <item>
         <title>Capitulo 2: Alambrado y protección </title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521261465</link>
         <description><![CDATA[<div>El artículo <strong>200 </strong>contiene las definiciones esenciales para la aplicación de esta NOM, se enfoca en el apartado "A" para equipos que operan a menos de 600 V</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 14:46:38 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521261465</guid>
      </item>
      <item>
         <title>Capitulo 3: Método de alambrado y materiales </title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521277496</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 14:50:28 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521277496</guid>
      </item>
      <item>
         <title>110-26:  Espacio de trabajo alrededor del equipo eléctrico de 600 volts o menos</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521282156</link>
         <description><![CDATA[<div>3) <strong>altura del espacio de trabajo </strong>habla de una excepción para unidades de vivienda donde se permitirá que los equipos de acometida y tableros de control no exceda los 200 amperes que estén instalados en espacios donde la altura de trabajo sea menor a los 2 metros</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 14:51:36 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521282156</guid>
      </item>
      <item>
         <title>200-3. Conexión a sistemas puestos a tierra</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521303553</link>
         <description><![CDATA[<div>&nbsp;Las instalaciones de los inmuebles no se deben conectar eléctricamente a la red de suministro a menos que esta última tenga, para cualquier conductor puesto a tierra de la instalación interior, el correspondiente conductor <mark>puesto a tierra.&nbsp;</mark></div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 14:56:35 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521303553</guid>
      </item>
      <item>
         <title></title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521310151</link>
         <description><![CDATA[<div>&nbsp;Conectado de modo que es capaz de transportar corriente, a diferencia de la conexión por inducción electromagnética&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 14:58:07 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521310151</guid>
      </item>
      <item>
         <title>200-6. Medios de identificación de conductores puestos a tierra</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521313772</link>
         <description><![CDATA[<div>&nbsp;b) Tamaño 21.2 mm2 (<strong>4 AWG</strong>) o <strong>mayores</strong>. Un conductor con aislamiento puesto a tierra de tamaño 21.2 mm2 (4 AWG), o mayor debe identificarse por medio de uno de los siguientes medios:<br>&nbsp; &nbsp; &nbsp; (1) Cubierta o aislamiento de color blanco en toda su longitud.<br>&nbsp; &nbsp; &nbsp; (2) Cubierta o aislamiento de color gris claro en toda su longitud.&nbsp;<br>&nbsp; &nbsp; &nbsp; (3) Tres franjas blancas a lo largo de toda la longitud del conductor, en conductores&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; que tengan aislamiento de color diferente al verde.&nbsp;<br>&nbsp; &nbsp; &nbsp; (4) En el momento de la instalación, por una marca distintiva blanca o gris en sus&nbsp; &nbsp; extremos. Esta marca debe rodear el conductor o el aislamiento&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 14:59:00 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521313772</guid>
      </item>
      <item>
         <title>210-3. Clasificación</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521342302</link>
         <description><![CDATA[<div>&nbsp;La clasificación de los <mark>circuitos </mark>derivados que no sean individuales debe ser de 15 hasta 50 amperes.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:05:29 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521342302</guid>
      </item>
      <item>
         <title>210-8: . Protección de las personas mediante interruptores de circuito por falla a tierra</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521354538</link>
         <description><![CDATA[<div>&nbsp;a) <strong>Unidades de vivienda</strong>. Todos los contactos en instalaciones monofásicas de 120 volts de 15 y 20 amperes&nbsp; deben ofrecer protección a las personas mediante interruptor de circuito por <mark>falla a tierra</mark>&nbsp; (ver lista de 8 incisos)</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:08:13 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521354538</guid>
      </item>
      <item>
         <title>210-11. Circuitos derivados requeridos. Se deben instalar circuitos derivados para iluminación y para aparatos según (210-10) &quot;Conductores de fase derivados de sistemas puestos a tierra&quot;</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521391724</link>
         <description><![CDATA[<div>&nbsp;c) Unidades de vivienda <br>&nbsp;1) Circuitos derivados para<strong> aparatos pequeños</strong> :&nbsp; instalar dos o más circuitos derivados de 20 amperes para aparatos pequeños&nbsp; además de los exigidos <br> 2) Circuitos derivados para <strong>lavadora</strong>: &nbsp; instalar al menos un circuito derivado de 20 amperes sin otras salidas, además de los exigidos<br> 3) Circuitos derivados para <strong>cuartos de baño</strong>: &nbsp; instalar al menos un circuito derivado de 20 amperes sin otras salidas, además de los exigidos</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:16:49 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521391724</guid>
      </item>
      <item>
         <title>210-12. Protección con interruptor de circuito por falla de arco</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521428221</link>
         <description><![CDATA[<div>&nbsp;a)<strong> Unidades de vivienda</strong>. Todos los circuitos derivados de 120 volts, de 15 y 20 amperes que alimenten salidas monofásicas instaladas en unidades de vivienda en: habitaciones familiares, comedores, salas de estar , etc. &nbsp;<br><br></div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:25:15 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521428221</guid>
      </item>
      <item>
         <title>Receptaculos</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521430871</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:25:53 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521430871</guid>
      </item>
      <item>
         <title>Interruptores</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521432474</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:26:17 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521432474</guid>
      </item>
      <item>
         <title>Circuitos</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521434449</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:26:44 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521434449</guid>
      </item>
      <item>
         <title>Alumbrados</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521436180</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:27:08 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521436180</guid>
      </item>
      <item>
         <title>Sistema a Tierra</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521437325</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:27:23 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521437325</guid>
      </item>
      <item>
         <title>  Las salidas de contactos deben instalarse como se especifica en 210-52 a 210-63. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521457566</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:31:52 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521457566</guid>
      </item>
      <item>
         <title>210-52.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521488254</link>
         <description><![CDATA[<div>para las salidas de contactos de 120 volts, 15 y 20 amperes.</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:38:13 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521488254</guid>
      </item>
      <item>
         <title></title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521492921</link>
         <description><![CDATA[<div>1- Sea parte de un aparato o una luminaria,</div><div>2-Esté controlado por interruptor de pared según 210-70(a)(1), Excepción 1,&nbsp;</div><div>3-Se instale en gabinetes o armarios.</div><div>4- Se instale a más de 1.70 metros por encima del piso.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:39:13 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521492921</guid>
      </item>
      <item>
         <title>Generalidades</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521532933</link>
         <description><![CDATA[<div>1-Cuarto de cocina<br>2-Salon<br>3-Biblioteca.<br>4-Cuarto de estudio.<br>5-Vesticulos.<br>etc.<br><br></div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:47:37 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521532933</guid>
      </item>
      <item>
         <title> c) Cubiertas. En los cuartos de cocinas, despensas, desayunador, comedores y áreas similares de lasunidades de vivienda</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521548112</link>
         <description><![CDATA[<div><strong>Ubicación de las salidas de contacto</strong>:</div><ul><li>&nbsp;Las salidas de contacto deben estar ubicadas en o sobre las cubiertas, pero a no más de 50 centímetros por encima de la cubierta.&nbsp;</li><li>Se permite que ensambles de salidas de contactos aprobadas para esta aplicación se instalen en las cubiertas.&nbsp;</li><li>Las salidas de contactos que no queden fácilmente accesibles debido a aparatos fijos, alacenas, fregadero o estufa sobrepuesta como los cubiertos en (c)(1), Excepción, o por aparatos que ocupen un espacio dedicado, no se deben considerar como parte de las salidas exigidas&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:50:43 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521548112</guid>
      </item>
      <item>
         <title>1) Separación. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521561014</link>
         <description><![CDATA[<ul><li>&nbsp;Deben instalarse de modo que ningún punto medido horizontalmente a largo de la línea del piso de cualquier espacio de pared esté a más de 1.80 metros.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:53:29 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521561014</guid>
      </item>
      <item>
         <title>2) Espacio de pared: </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521570766</link>
         <description><![CDATA[<div>&nbsp;1-Cualquier espacio de 60 centímetros o más de ancho incluyendo el espacio que se mida en las esquinas y no interrumpido por aberturas de puertas o aberturas similares, chimeneas y gabinetes fijos.<br>&nbsp;2-El espacio ocupado por paneles fijos en paredes exteriores, excepto los paneles deslizantes.&nbsp;<br>3- El espacio creado por divisores fijos de cuartos tales como mostradores autosoportados tipo bar o barandillas.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:55:28 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521570766</guid>
      </item>
      <item>
         <title>210-70. Salidas requeridas para alumbrado. Las salidas para alumbrado deben instalarse donde se especifica </title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521575662</link>
         <description><![CDATA[<div>&nbsp;a)<strong> Unidad o unidades de vivienda.</strong> En las unidades de vivienda, las salidas de alumbrado deben instalarse de acuerdo a las siguientes disposiciones. <br>1) Cuartos habitables. Debe instalarse al menos una salida para <mark>alumbrado</mark> controlada por un interruptor de pared, en todos los cuartos habitables y cuartos de baño. <br><br><em>Excepción 1</em>: En otros lugares diferentes de cocinas y cuartos de baño se permite uno o más contactos controlados mediante interruptor de pared en lugar de salidas de alumbrado. <br><br><em>Excepción 2</em>: Se permite que las salidas de alumbrado estén controladas por sensores de presencia que (1) Sean complementarios a los interruptores de pared, o (2) estén situados donde se instalan normalmente los interruptores de pared y estén equipados con un control manual adicional que permita que el sensor funcione como interruptor de pared.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:56:32 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521575662</guid>
      </item>
      <item>
         <title>3) Contactos de piso.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521588122</link>
         <description><![CDATA[<ul><li>&nbsp;Los contactos de piso no deben contarse como parte del número requerido de salidas de contactos, a menos que estén localizados a una distancia no mayor de 45 centímetros de la pared.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 15:59:11 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521588122</guid>
      </item>
      <item>
         <title>4) Contactos en las cubiertas.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521607474</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:03:18 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521607474</guid>
      </item>
      <item>
         <title>220-12. Cargas de alumbrado para lugares específicos</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521611412</link>
         <description><![CDATA[<div>&nbsp;La carga mínima de alumbrado por cada metro cuadrado de superficie del piso, debe ser mayor o igual que la especificada en la Tabla 220-12&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:04:08 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521611412</guid>
      </item>
      <item>
         <title></title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521616288</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1066866055/5ccaceda820d63c4dc5da58f16f67eb0/image.png" />
         <pubDate>2021-05-13 16:05:09 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521616288</guid>
      </item>
      <item>
         <title>b) Aparatos pequeños.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521616756</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:05:16 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521616756</guid>
      </item>
      <item>
         <title>1) Salidas para contactos alimentados.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521617728</link>
         <description><![CDATA[<ul><li>&nbsp;En la cocina, despensa, comedor, desayunador o área similar de una unidad de vivienda, los dos o más circuitos derivados de 20 amperes para aparatos pequeños.</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:05:29 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521617728</guid>
      </item>
      <item>
         <title></title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521623817</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1066866055/8ed488d5fe54d69affd8658511e27279/image.png" />
         <pubDate>2021-05-13 16:06:50 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521623817</guid>
      </item>
      <item>
         <title>2) Ninguna otra salida. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521641222</link>
         <description><![CDATA[<ul><li>&nbsp;Los dos o más circuitos derivados para aparatos pequeños especificados en 210-52 (b)(1) no deben tener salidas para otros propósitos.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:10:40 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521641222</guid>
      </item>
      <item>
         <title>3) Requisitos para contactos en la cocina.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521735007</link>
         <description><![CDATA[<div>&nbsp;Los contactos instalados en las cubiertas de una cocina, deben estar alimentados cuando menos por dos circuitos derivados de aparatos pequeños, se permitirá que cada uno de estos circuitos, o ambos, también alimenten salidas de contacto en el mismo cuarto de cocina y en otros cuartos especificados&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:30:50 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521735007</guid>
      </item>
      <item>
         <title>680-22. Iluminación, contactos y equipo</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521812643</link>
         <description><![CDATA[<div>&nbsp;3) Unidad(es) de vivienda. Cuando haya una alberca permanente en una(s) unidad(es) de vivienda,</div><ul><li>Debe haber por lo menos un contacto de 120 volts de 15 ó 20 amperes alimentado por un circuito derivado de uso general</li><li>Ubicado cuando menos a 1.85 metros de las paredes interiores de la alberca, pero cuando mucho a 6.00 metros de la pared interior de la alberca.</li><li>&nbsp;Este contacto debe estar ubicado a no más de 2.00 metros de altura sobre el nivel del piso, plataforma o nivel de las gradas sirviendo a la alberca.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:47:30 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521812643</guid>
      </item>
      <item>
         <title>3) Requisitos para contactos en la cocina.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521853651</link>
         <description><![CDATA[<div>&nbsp;Los contactos instalados en las cubiertas de una cocina, deben estar alimentados cuando menos por dos circuitos derivados de aparatos pequeños, se permitirá que cada uno de estos circuitos, o ambos, también alimenten salidas de contacto en el mismo cuarto de cocina y en otros cuartos especificados en (b)(1). Se permitirán circuitos derivados adicionales que alimenten las salidas de contactos de la cocina y de otras habitaciones especificadas en (b)(1). Ningún circuito derivado para pequeños aparatos debe alimentar más de una cocina.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:56:12 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521853651</guid>
      </item>
      <item>
         <title>Cubiertas</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521856725</link>
         <description><![CDATA[<ul><li>&nbsp;En los cuartos de cocinas, despensas, desayunador, comedores y áreas similares de las unidades de vivienda se deben instalar salidas de contacto para las cubiertas.</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:56:52 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521856725</guid>
      </item>
      <item>
         <title>1) Espacio de pared de la cubierta. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521861196</link>
         <description><![CDATA[<ol><li>&nbsp;Se debe instalar un contacto en cada espacio de pared de la cubierta que tenga 30 centímetros o más de ancho.&nbsp;</li><li>Las salidas de contacto se deben instalar de modo que ningún punto a lo largo de la línea de la pared quede a más de 60 centímetros, medido horizontalmente, desde un contacto en ese espacio.&nbsp;</li></ol>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:57:52 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521861196</guid>
      </item>
      <item>
         <title>2) Espacios en las cubiertas de isla. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521870347</link>
         <description><![CDATA[<ul><li>&nbsp;Se debe instalar por lo menos un contacto en cada cubierta de isla cuya dimensión más larga tenga 60 centímetros o más y la más corta 30 centímetros o más.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 16:59:45 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521870347</guid>
      </item>
      <item>
         <title>3) Espacios en las cubiertas de península.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521873297</link>
         <description><![CDATA[<ul><li>&nbsp;En cada cubierta de península, cuya dimensión más larga tenga 60 centímetros o más y la más corta 30 centímetros o más, se debe instalar por lo menos una salida de contacto.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:00:25 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521873297</guid>
      </item>
      <item>
         <title>680-22. Iluminación, contactos y equipo</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521876737</link>
         <description><![CDATA[<div>&nbsp;4) Protección con interruptores de circuito contra <mark>fallas a tierra.</mark> Todos los contactos monofásicos de 120 volts, de 15 ó 20 amperes, ubicados a una distancia máxima de 6.00 metros de las paredes interiores de la alberca deben estar protegidos por un interruptor de circuito contra fallas a tierra.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:01:12 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521876737</guid>
      </item>
      <item>
         <title>4) Espacios separados. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521877614</link>
         <description><![CDATA[<div>&nbsp;Para aplicar los requisitos del inciso (1) anterior, se deben considerar como espacios separados las cubiertas separados por estufas, refrigeradores o fregaderos. Si una estufa, una parrilla de cubierta o un fregadero son instalados en mesones de isla o de península y la profundidad de la cubierta por detrás de la estufa, parrilla de cubierta o fregadero es menor a 30 centímetros, se debe considerar que la estufa, la parrilla de cubierta o el fregadero dividen el espacio de la cubierta en dos espacios de cubiertas separadas. </div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:01:24 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521877614</guid>
      </item>
      <item>
         <title>d) Cuartos de baño</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521888966</link>
         <description><![CDATA[<ol><li>&nbsp;En los cuartos de baño de unidades de vivienda se debe instalar por lo menos un contacto a no más de 90 centímetros del borde exterior de cada lavabo.&nbsp;</li><li>Las salidas de contacto se deben localizar en una pared o una división que sea adyacente al lavabo o a la cubierta del lavabo, localizadas en la cubierta, o se debe instalar en la superficie lateral o frontal del gabinete del lavabo a no más de 30 centímetros por debajo de la cubierta.&nbsp;</li></ol>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:03:56 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521888966</guid>
      </item>
      <item>
         <title>e) Salidas exteriores.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521893740</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:04:55 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521893740</guid>
      </item>
      <item>
         <title>690-45. Tamaño del conductor de puesta a tierra de equipos.</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521895954</link>
         <description><![CDATA[<div>&nbsp;Los conductores de puesta a tierra de equipos para circuitos de fuentes fotovoltaicas y circuitos de salida fotovoltaica se deben dimensionar de acuerdo con: <br>&nbsp;b) <strong>Sin protección contra fallas a tierra</strong>. Para lugares diferentes a las unidades de vivienda donde no se suministra protección contra fallas a tierra, de acuerdo con 690-5(a) hasta (c), cada conductor de puesta a tierra de equipos debe tener una ampacidad de por lo menos dos (2) veces la ampacidad corregida por ocupación del tubo conduit y por temperatura del conductor del circuito&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:05:24 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521895954</guid>
      </item>
      <item>
         <title>1) Viviendas unifamiliares y bifamiliares.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521897249</link>
         <description><![CDATA[<ul><li>Se debe instalar al menos una salida de contacto accesible mientras se está de pie al nivel del suelo y que esté ubicado a no más de 2.00 metros sobre el suelo, en la parte frontal y posterior de la vivienda.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:05:43 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521897249</guid>
      </item>
      <item>
         <title>2) Viviendas multifamiliares.</title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521901886</link>
         <description><![CDATA[<ul><li>&nbsp; Se debe instalar por lo menos una salida de contacto accesible desde el suelo y a no más de 2.00 metros por encima del suelo&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:06:49 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521901886</guid>
      </item>
      <item>
         <title>3) Balcones, terrazas y pórticos. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521906662</link>
         <description><![CDATA[<ol><li>&nbsp; Accesibles desde el interior de la vivienda deben tener por lo menos una salida de contacto instalada dentro del perímetro .&nbsp;</li><li>El contacto no debe estar a más de 2.00 metros por encima de la superficie del balcón, terraza o pórtico.&nbsp;</li></ol>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:07:56 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521906662</guid>
      </item>
      <item>
         <title>f) Areas de lavadora. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521910119</link>
         <description><![CDATA[<ul><li>&nbsp;En las unidades de vivienda se debe instalar como mínimo una salida de contacto para la lavadora.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:08:46 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521910119</guid>
      </item>
      <item>
         <title>g) Sótanos, garajes y edificios accesorios. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521916747</link>
         <description><![CDATA[<div>&nbsp;En las viviendas unifamiliares se deben aplicar las siguientes disposiciones:</div><ol><li>&nbsp;En todos los&nbsp; accesorios que tengan instalación eléctrica, se debe instalar por lo menos una salida de contacto adicional a aquellos para equipo específico.</li><li>&nbsp; Cuando una parte del sótano tiene construido uno o más espacios habitables, cada parte independiente no terminada debe tener una salida de contacto instalada.&nbsp;</li></ol>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:10:22 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521916747</guid>
      </item>
      <item>
         <title>800-156. Salida para comunicaciones en unidades de vivienda</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521916930</link>
         <description><![CDATA[<div>&nbsp;En construcciones de unidades de vivienda nuevas, se debe instalar cuando menos una salida para comunicaciones, en un área fácilmente accesible y cableada hasta el punto de entrega del suministrador del servicio.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:10:25 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521916930</guid>
      </item>
      <item>
         <title>h) Pasillos. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521920172</link>
         <description><![CDATA[<ul><li>&nbsp;En las unidades de vivienda, los pasillos de 3.00 metros o más de longitud deben tener por lo menos una salida de contacto.&nbsp;</li></ul><div><br></div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:11:09 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521920172</guid>
      </item>
      <item>
         <title>i) Vestíbulos. </title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521923534</link>
         <description><![CDATA[<ul><li>Deben tener un contacto localizado en cada espacio de pared de 90 centímetros o más de ancho, que no sean interrumpidos por entradas, ventanas del piso al techo y aberturas similares.&nbsp;</li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:11:58 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521923534</guid>
      </item>
      <item>
         <title></title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521932190</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1066866055/6f4bb04a29d51ec6c7feb836c8d7b0a6/image.png" />
         <pubDate>2021-05-13 17:14:03 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521932190</guid>
      </item>
      <item>
         <title></title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521975931</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1066866055/b60e4e29ba84a3eeeaff034d0653ad5a/image.png" />
         <pubDate>2021-05-13 17:24:16 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521975931</guid>
      </item>
      <item>
         <title>Electrodo puesto a tierra</title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521978715</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:24:52 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521978715</guid>
      </item>
      <item>
         <title>820-100. Conductores de unión y conductores de electrodo de puesta a tierra. </title>
         <author>davidlevioyloria</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521986968</link>
         <description><![CDATA[<div>&nbsp;a) <strong>Conductor de unión y conductor de electrodo de puesta a tierra</strong>. <br>Aislamiento, material, tamaño, longitud, tendido en líneas, protección mecánica<br><br> b) <strong>Electrodo </strong><br>&nbsp;1) En edificios o estructuras con una terminal de unión Inter sistemas. <br>&nbsp;2) En edificios o estructuras con medios de puesta a tierra <br><br>&nbsp;c<strong>) Conexión a los electrodos</strong>. <br> Las conexiones a los electrodos de puesta a tierra deben cumplir con 250-70. <br><br> d) <strong>Unión de los electrodos</strong>&nbsp;<br> Un puente de unión de tamaño no menor que 13.3 mm2 (6 AWG) de cobre o equivalente, se debe conectar entre el electrodo de puesta a tierra del sistema de antena de televisión comunal y el sistema de electrodos de puesta a tierra de la alimentación del edificio o estructura alimentada, cuando se usan electrodos separados.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-13 17:26:40 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1521986968</guid>
      </item>
      <item>
         <title></title>
         <author>chucho11162</author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1523313906</link>
         <description><![CDATA[<div>Se podrán proteger con un interruptor de circuito por fallas de arco, instalado para brindar protección al circuito derivado.&nbsp;</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-14 01:45:46 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1523313906</guid>
      </item>
      <item>
         <title>404. Desconectadores</title>
         <author></author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1523399768</link>
         <description><![CDATA[<div>Generalidades de Interruptores a 600 V o menos, lo que incluye viviendas.</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-14 02:18:16 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1523399768</guid>
      </item>
      <item>
         <title>Modificaciones o extensiones de circuitos derivados-Unidades de vivienda</title>
         <author></author>
         <link>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1523437564</link>
         <description><![CDATA[<div>Cuando el alambrado del circuito derivado se modifica, reemplaza o<br>amplía, se podrá proteger el circuito derivado con una de las siguientes opciones:<br>(1) Un interruptor de circuito por falla de arco tipo combinación aprobado, localizado en el origen del<br>circuito derivado.<br>(2) Un interruptor de circuito por falla de arco tipo salida aprobado, localizado en la primera salida<br>del circuito derivado existente.</div>]]></description>
         <enclosure url="" />
         <pubDate>2021-05-14 02:33:22 UTC</pubDate>
         <guid>https://padlet.com/davidlevioyloria/q2huone7m8wmmt6e/wish/1523437564</guid>
      </item>