         <title>rotating anode x-rays tubes</title>
         <author>liberm</author>
         <link>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449873817</link>
         <description><![CDATA[<div>Rotating anodes in x-ray tubes are made of rhenium, tungsten, and molybdenum alloy. Its rotating speed is 3,600 to 10,000 revolutions per minute. The rotating the anode helps heat that is produced to be dispersed, and the tube current can be increased to increase the intensity of X-rays. The rotating anodes can also produces a heterogeneous beam of radiation</div>]]></description>
         <enclosure url="https://img.medicalexpo.com/images_me/photo-mg/68810-16210557.jpg" />
         <pubDate>2023-01-19 14:35:59 UTC</pubDate>
         <guid>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449873817</guid>
      </item>
      <item>
         <title>X rays tube in Helical/spiral</title>
         <author>liberm</author>
         <link>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449873931</link>
         <description><![CDATA[<div>Helical/spiral scanners have additional tube requirements and demands that sustain higher power levels which can withstand additional heat generation and help dissipate heat.</div>]]></description>
         <enclosure url="https://image3.slideserve.com/6752488/helical-spiral-ct-l.jpg" />
         <pubDate>2023-01-19 14:36:02 UTC</pubDate>
         <guid>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449873931</guid>
      </item>
      <item>
         <title>Tube envelope and anode assembly</title>
         <author>liberm</author>
         <link>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449874088</link>
         <description><![CDATA[<div>The tube envelope has a vacuum which provides structural support and and high insulation of the anode and cathode. The anode has a disk, rotor, rotor stud and hub, and bearings</div>]]></description>
         <enclosure url="https://o.quizlet.com/fVKd4RGVUbhXPvQEiwNOnA_b.png" />
         <pubDate>2023-01-19 14:36:09 UTC</pubDate>
         <guid>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449874088</guid>
      </item>
      <item>
         <title>Filtration</title>
         <author>liberm</author>
         <link>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449874174</link>
         <description><![CDATA[<div>Filtration reduces x-ray intensity, but not the maximum energy of the x-ray beam spectrum. There are two types of filtration: inherent and added filtration. Inherent filtration shapes the energy distribution across the radiation beam to produce uniform beam hardening and added filtration helps solves beam hardening effect for the CT detector system</div>]]></description>
         <enclosure url="https://cdn.slidesharecdn.com/ss_thumbnails/x-rayfilters-190313120636-thumbnail-4.jpg?cb=1552478951" />
         <pubDate>2023-01-19 14:36:12 UTC</pubDate>
         <guid>https://padlet.com/liberm/hv6motjv5235zh59/wish/2449874174</guid>