<?xml version="1.0"?>
<rss version="2.0">
   <channel>
      <title>Audits in civil works by JAVIER CASTILLO</title>
      <link>https://padlet.com/JavierCastillobau/h1gz3h6o760i</link>
      <description>Practice conducting environmental audits</description>
      <language>en-us</language>
      <pubDate>2019-05-03 03:28:32 UTC</pubDate>
      <lastBuildDate>2019-11-30 03:01:24 UTC</lastBuildDate>
      <webMaster>hello@padlet.com</webMaster>
      <image>
         <url>https://imgglb.padletcdn.com/v13/image?t=g_auto&amp;url=https%3A%2F%2Fpadlet.net%2Ficons%2Fpng%2F1f600.png</url>
      </image>
      <item>
         <title>AUDIT OF THE CONSTRUCTION PROJECT DOMESTIC RESIDUAL WATER TREATMENT PLANT FOR THE URBAN AREA OF THE MUNICIPALITY OF SAMACÁ, BOYACÁ, PHASE 1</title>
         <author>JavierCastillobau</author>
         <link>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356473628</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2019-05-03 03:36:56 UTC</pubDate>
         <guid>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356473628</guid>
      </item>
      <item>
         <title>This work is located in the municipality of Samaca, this project is the construction of a Wastewater Treatment Plant, which will treat residential wastewater from the municipality and later dispose the treated water to a stream to be used As irrigation for the crops, the treatment will be carried out by means of an anaerobic method, in the project eight people are linked, including the resident engineer and the legal representative of the work. the project still does not have an isolation, which means that it is in view of the entire population and due to this everyone has access to the work.</title>
         <author>JavierCastillobau</author>
         <link>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356475307</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2019-05-03 03:49:40 UTC</pubDate>
         <guid>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356475307</guid>
      </item>
      <item>
         <title>During the audit the information was reviewed and from this the respective findings could be established.In which we find that the work barely had eight days to start work. The work does not have the stationery or supports of environmental origin, only project plans are shown with all the sectors of the plant. An ecological point has not yet been determined. The main economic activity in the surrounding land is agriculture in which different types of fungicides and herbicides are applied that can affect the project directly. The workers and collaborators of the work do not have any type of security element for the development of their work. There is no evidence of the presence of security elements such as stretchers, first aid kit and fire extinguisher inside the work. It has a land collection yard which is not marked or demarcated. It does not have a restriction or isolation zone for the entry of people outside the work. A reservoir of water was found during the drilling and excavation. It still does not have an organization chart where the good functioning of the work is evidenced.</title>
         <author>JavierCastillobau</author>
         <link>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356475803</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2019-05-03 03:53:28 UTC</pubDate>
         <guid>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356475803</guid>
      </item>
      <item>
         <title>During the course of the field trip of the Environmental Audit, it was possible to demonstrate that in relation to sensitive areas and risks that in general the constructive characteristics of the WWTP do not present risks to the socio-environmental dynamics of the area. The work had barely had 8 days of operations since the day of the audit, in which they had excavated approximately 4 meters deep where they found a water deposit that has been hampering the development of the project. These zones do not count without a demarcation or restrictions or any safety method for workers and visitors.In spite of the short time of activities you should already have all the requirements that are given by the regulations to be able to start with their construction activities.</title>
         <author>JavierCastillobau</author>
         <link>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356475889</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2019-05-03 03:54:13 UTC</pubDate>
         <guid>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356475889</guid>
      </item>
      <item>
         <title>In spite of the short time that they had started the construction of the plant, they should have all the protection tools and have an organization in such a way that meets all the requirements of the applied regulations.</title>
         <author>JavierCastillobau</author>
         <link>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356476219</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2019-05-03 03:57:01 UTC</pubDate>
         <guid>https://padlet.com/JavierCastillobau/h1gz3h6o760i/wish/356476219</guid>
      </item>
   </channel>