<?xml version="1.0"?>
<rss version="2.0">
   <channel>
      <title>RED TENSADA DE BT IBERDROLA  by Cherif Adrame Diadiou Sarr</title>
      <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4</link>
      <description></description>
      <language>en-us</language>
      <pubDate>2023-11-22 13:01:31 UTC</pubDate>
      <lastBuildDate>2023-11-30 15:45:07 UTC</lastBuildDate>
      <webMaster>hello@padlet.com</webMaster>
      <image>
         <url>https://padlet.net/icons/png/2694.png</url>
      </image>
      <item>
         <title>RED AÉREA TENSADA DE BAJA TENSIÓN</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2800567419</link>
         <description><![CDATA[]]></description>
         <enclosure url="" />
         <pubDate>2023-11-23 11:12:42 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2800567419</guid>
      </item>
      <item>
         <title>CARACTERISTICAS</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2800568118</link>
         <description><![CDATA[<ul><li><p>Se establece un factor de potencia de valor cos φ = 0,9, que corresponde a un reparto</p><p>normal para alumbrado y suministros industriales, tanto en zonas urbanas como rurales.</p></li></ul>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/2149754556/8b7c0d361eff15530a592cdd2180aa48/image.png" />
         <pubDate>2023-11-23 11:13:25 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2800568118</guid>
      </item>
      <item>
         <title>CABLES</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2800568236</link>
         <description><![CDATA[<p>Las especificaciones de los cables se indican en la norma NI 56.36.01 y Normas UNE, responden a la denominación genérica “RZ” y se dividen en dos grupos</p><ul><li><p>Redes de distribucion</p></li><li><p>acometida</p></li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2023-11-23 11:13:32 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2800568236</guid>
      </item>
      <item>
         <title>Materiales</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809165582</link>
         <description><![CDATA[<p>La construcción de las redes aéreas de baja tensión se realizará con materiales normalizados&nbsp; en normas de Iberdrola</p>]]></description>
         <enclosure url="" />
         <pubDate>2023-11-30 14:55:16 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809165582</guid>
      </item>
      <item>
         <title>Cable para redes de distribucion</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809170714</link>
         <description><![CDATA[<p>Están formadas por tres conductores de fase (aluminio) y un conductor neutro; este último es autoportante de aleación de aluminio duro (almelec) y tiene 29,5, 54,6 ó 80 mm2 de sección.</p>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/2149754556/26f0d05f11729a87a4a22b9ecbcf3912/image.png" />
         <pubDate>2023-11-30 14:58:29 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809170714</guid>
      </item>
      <item>
         <title>Cable para la acometida</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809172369</link>
         <description><![CDATA[<p>Es la parte de la instalación comprendida entre la red de distribución y la caja general de protección.</p><p>Están formadas por dos o cuatro conductores de aluminio de las secciones siguientes:</p><p>2x16, 2x25 y 4x16</p>]]></description>
         <enclosure url="" />
         <pubDate>2023-11-30 14:59:36 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809172369</guid>
      </item>
      <item>
         <title>APOYOS</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809193851</link>
         <description><![CDATA[<ul><li><p>Los apoyos pueden ser tanto de HORMIGON ARMADO VIBRADO o APOYOS DE CHAPA METALICA</p></li></ul><ul><li><p> Los apoyos pueden tener un tense maxima de  500daN  o de 315daN</p></li></ul>]]></description>
         <enclosure url="" />
         <pubDate>2023-11-30 15:13:28 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809193851</guid>
      </item>
      <item>
         <title>TABLA DE TENDIDOS</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809215794</link>
         <description><![CDATA[<p>Dependiendo del conductor utilizado ; de la zona (A,B o C) y de la traccion maxima(daN) se elige que tabla de tendido hay que utilizar.</p>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/2149754556/da7fd3de53604d529afd59a3fa858ecf/image.png" />
         <pubDate>2023-11-30 15:25:41 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809215794</guid>
      </item>
      <item>
         <title></title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809220735</link>
         <description><![CDATA[<p>B justifican la utilización de los apoyos, en función del ángulo de desviación de la línea y del vano.</p><p><br></p>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/2149754556/54d156fa48d280d79b872b5fd954f6b5/image.png" />
         <pubDate>2023-11-30 15:29:19 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809220735</guid>
      </item>
      <item>
         <title>Cimentaciones para apoyos</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809234869</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/2149754556/729e006bc689e8bf3cf11a691b7de10c/image.png" />
         <pubDate>2023-11-30 15:38:37 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809234869</guid>
      </item>
      <item>
         <title>Puesta de tierra del Neutro</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809237895</link>
         <description><![CDATA[<p>El conductor neutro, además de la puesta a tierra del centro de transformación, se pondrá a</p><p>tierra en otros puntos, y como mínimo, una vez cada 300 m de longitud de la línea,</p><p><br/></p>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/2149754556/1768211b19fe048069b22dd14f394d01/image.png" />
         <pubDate>2023-11-30 15:40:46 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809237895</guid>
      </item>
      <item>
         <title>Cajas Generales de Protección (CGP).</title>
         <author>20cdiadiou</author>
         <link>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809244439</link>
         <description><![CDATA[<p>Las CGP se instalarán en terreno propiedad del cliente, situándose empotradas o sobre fachadas, a una</p><p>altura mínima de 3 m y con acceso directo desde la vía pública.</p>]]></description>
         <enclosure url="" />
         <pubDate>2023-11-30 15:45:01 UTC</pubDate>
         <guid>https://padlet.com/20cdiadiou/a7kbp053dkcvqnu4/wish/2809244439</guid>
      </item>