<?xml version="1.0"?>
<rss version="2.0">
   <channel>
      <title>RGC Past Year Paper 2007 by charles sarimuthu</title>
      <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t</link>
      <description>Revision Sem Jan-Apr 2019</description>
      <language>en-us</language>
      <pubDate>2019-04-03 08:59:48 UTC</pubDate>
      <lastBuildDate>2024-07-15 11:47:49 UTC</lastBuildDate>
      <webMaster>hello@padlet.com</webMaster>
      <image>
         <url></url>
      </image>
      <item>
         <title>Question 2</title>
         <author>charles_sarimuthu</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347975719</link>
         <description><![CDATA[<div>Part 2 (DFIG)</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398379/c0bd4d0d6c8dbc480d8f4b2825cc9259/WhatsApp_Image_2019_04_03_at_17_30_24.jpeg" />
         <pubDate>2019-04-03 09:08:26 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347975719</guid>
      </item>
      <item>
         <title>Question 3</title>
         <author>charles_sarimuthu</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347975791</link>
         <description><![CDATA[<div>3. (a)<br>(i) Pneumatic<br>(ii) Hydraulic linkage<br>(iii) Mechanical linkage<br>(iv) Hydraulic Linkage<br>(v) Direct drive<br><br>3. (b) image<br>Archimedes - linear generator (directly connected to grid)<br>Pelamis - DFIG (AC/DC/AC conversion to grid)<br><br>3. (c)<br>Underwater cables<br>+ does not disrupt scenery<br>- high maintenance cost and risk<br><br>Above water cable<br>-pros and cons opposite of underwater cable<br><br>3. (d)<br>Energy generated<br>= 500kW*0.4*8760hours<br>=1752MWh<br>nHouses<br>=1752MWh/4377kWh<br>=400houses<br><br>3. (e) P = 1/2 pAv^3<br>1MW marine current turbine: <br>2knots = 2*1.85*1000/(60*60)<br>2knots = 1.0278 m/s<br><br>A = 1*10^6 / (0.5*1020*1.0278^3)<br>A = 1806 m^2<br>πr^2 = 1806<br>d = 2*r = 48m<br><br>1MW wind turbine:<br>A = 1*10^6 / (0.5*1.2*15^e)<br>A = 493.8 m^2<br>d = 2*r = 25m</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398353/12c43125bea727762a339e69837522dc/df83f81f_4bbe_4dcc_83da_27a34854b9a7.jpg" />
         <pubDate>2019-04-03 09:08:43 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347975791</guid>
      </item>
      <item>
         <title>Question 4</title>
         <author>charles_sarimuthu</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347975826</link>
         <description><![CDATA[<div>4. (a)<br>Ocean Wave Power<br>- Generally island communities have fuel energy imported at considerable cost. OWE conversion is very attractive when the minimum sea state condition required around the island facilities energy conversion. <br>- Peninsular Malaysia and East Malaysia is surrounded by ocean at multiple sides.<br>- They do not require any external fuel and do not cause any pollution.<br>- Relatively inexpensive to build as it only affects a small area.<br><br>OffShore Wind Power<br>- Only possible to harvest during monsoon season (November to March) as wind wave direction from north-east of Malaysia is predominant and monsoon season (May to September) as wind wave direction from south-west is predominant. <br>- Wind wave energies swell in their respective areas during these 2 seasons.<br>- Would be cost-inefficient if building a wind power generation system as there are only 2 high wind seasons in Malaysia.<br><br><br>4. (b)<br>Ocean Wave Power<br>- Structures have to withstand harsh and adverse environment specific to the nature of the sea. <br>Solution reliable design with tried and test components, safety mechanisms in storms can involve sinking the structure <br>- Peak power is generally available in deep sea far from land. <br>Optimise ocean topography nearer land and/or reliable design in deep sea with minimal complexity <br>- Wave frequency 0.1Hz is difficult to couple to generator frequency 50Hz. Solution is coupling <br><br>OffShore Wind Power <br>-Depending on the height of the wind tower,  high windspeeds may damage the turbine blades. <br>- That can be solved through active pitch control and stall control and also aids in maximizing output for all winds.<br><br>4. (c)<br>Ocean Wave Power<br>- Wave power conversion has been demonstrated technically but not economically.<br>- Significant resource but has been one of the last to be developed. <br>- Important criteria is simplicity and reliability, technically complex plants lacking well-proven technology are fundamentally untenable for OWC projects.<br><br>OffShore Wind Power <br>- Very stable and still growing in overseas but not in Malaysia.<br><br><br><br>4. (d)<br>Ocean Wave Power<br> - Large capital costs of the structures involved <br>- Can be installed in groups rather than singularly <br>- Clusters offer a better proposition than individual units because of maintenance, installation and operating costs are then spread over a much larger total generating capacity. <br><br>OffShore Wind Power <br>- Large start-up costs for manufacturing, setting up and shipping rotor blades and building up a wind tower.<br>- Maintenance cost will be very high as it is very difficult to work around offshore and high towers.<br>- Requires a very long time to return on investment.<br><br>4. (e)<br>Ocean Wave Power<br>- Direct Drive <br>wave &gt; special electrical machine<br>- Hydraulic<br>wave &gt; piston &gt; high pressure oil &gt; pipe &gt; hydraulic motor &gt; conventional electrical machine &gt;<br>- Mechanical Linkage<br>wave &gt; velocity increase &gt; conventional electrical machine<br><br>OffShore Wind Power</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398357/60d8bbad147e06346de0f087f80746d9/IG.jpg" />
         <pubDate>2019-04-03 09:08:48 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347975826</guid>
      </item>
      <item>
         <title>Q1 (g)(i) Direct-coupled PV system</title>
         <author>kas71</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347984577</link>
         <description><![CDATA[<div><strong>PV Array<br></strong>- Converts solar energy to electrical energy (DC)<br><strong>DC Load<br></strong>- Draws DC power from the PV array<br>(The DC load determines the operating point) </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398374/5e35946713a79256d3af1f2f9daf06c6/image.png" />
         <pubDate>2019-04-03 09:42:36 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347984577</guid>
      </item>
      <item>
         <title>Q1 (a,b)</title>
         <author>zu3</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347985000</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370750065/2c9da643cae21c54621fdee0911be7c6/image.png" />
         <pubDate>2019-04-03 09:43:59 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347985000</guid>
      </item>
      <item>
         <title>Question 1</title>
         <author>zu3</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347985118</link>
         <description><![CDATA[<div><strong>(c)</strong>  Maximum power point (MPP) is the point on a power (I-V) curve that has the highest value of the product of its corresponding voltage and current (aka highest power output) <br><br><strong>(d) </strong>Hill-climbing algorithm starts by calculating the Power from measured Voltage and Current, then compared to the previous results to obtain difference in power and voltage. Slope=(Difference in power)/(Difference in voltage). <br>If the slope is &gt;0, duty cycle will be increased so voltage is increased.<br>If the slope is &lt;0, duty cycle will be decreased so voltage is decreased.<br>Measurements required = Voltage, Current, Solar radiation level, Irradiance level<br><strong>(e)</strong><br><br><strong>(f)</strong> Bypass diodes allow series of connected PV cells to continue supplying power at a reduced voltage rather than no power at all. This means if one of the PV cells has a defect or does not have solar radiation, the rest of the PV cells can still continue to supply current.</div>]]></description>
         <enclosure url="" />
         <pubDate>2019-04-03 09:44:31 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347985118</guid>
      </item>
      <item>
         <title>Question 2</title>
         <author>tab33</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347986536</link>
         <description><![CDATA[<div>Part 2 (Direct Connected)</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398379/0e16f7e02e63b24fe1efde2c457e0aa7/WhatsApp_Image_2019_04_03_at_17_30_24__1_.jpeg" />
         <pubDate>2019-04-03 09:49:30 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347986536</guid>
      </item>
      <item>
         <title>Q1 (g)(ii) Stand-alone PV system</title>
         <author>kas71</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347986594</link>
         <description><![CDATA[<div><strong>Charge Controller</strong><br>-Control the flow of current to the battery and prevents the battery from over-charging.<br><strong>Battery</strong><br>-Stores electrical energy<br>Inverter<br>-Converts DC to AC<br>(The charge controller determines the operating point </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398374/fedcee0bd9153d4f7c9bd9c1c2a6ffa2/image.png" />
         <pubDate>2019-04-03 09:49:41 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347986594</guid>
      </item>
      <item>
         <title>Question 2</title>
         <author>tab33</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347986981</link>
         <description><![CDATA[<div>Part 2 (Direct-drive synchronous)</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398379/61439a96d74fb93a41f13d6b713a2aa6/WhatsApp_Image_2019_04_03_at_17_30_24__2_.jpeg" />
         <pubDate>2019-04-03 09:51:04 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347986981</guid>
      </item>
      <item>
         <title>Q1 (g)(iii) Grid-connected PV system</title>
         <author>kas71</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347987933</link>
         <description><![CDATA[<div><strong>Inverter/Power Conditioner<br></strong>-Converts DC to AC that matches the grid<br>-Controls the power flow of the PV array<br><strong>Distribution Panel<br></strong>-distributes the power flow accordingly<br><strong>Electric Utility<br></strong>-The AC power grid that connects to the distribution network<br>(The Power Conditioner determines the operating point)</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398374/6d601ad3f0a8b6e046f5a8533d7e98aa/image.png" />
         <pubDate>2019-04-03 09:54:30 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347987933</guid>
      </item>
      <item>
         <title>Question 2 </title>
         <author>tab33</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347989018</link>
         <description><![CDATA[<div>Part 1:<br> </div><div>The General advantages: <br>– Clean source of energy <br>– Globally available <br>– One of the lowest priced RE technologies <br>– Application in urban and rural environments. <br><br>The General disadvantages: <br>– Has to compete with conventional on a cost basis <br>– Remote locations for the best sites <br>– Issues relating to noise and effective “condition monitoring” <br>– Wind is intermittent, akin to many RE resources. </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370398379/048f009b2c398e0b7e9b122f30a4f758/Capture1.jpg" />
         <pubDate>2019-04-03 09:58:42 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347989018</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347992811</link>
         <description><![CDATA[<div>Q3 (b) Pelamis and AWS<br>The Pelamis uses a hydraulic motor. Hydraulic motor is operated by pressure differential between two sides of the motor. <br>AWS uses Linear Generator. Linear motion directly converted to electricity.<br><br>both use AC-DC-AC Converter. the generator side diode rectifier no requirement for DC. grid side inverter outputs power at grid frequency and voltage.</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/370753871/f96f48f6ff77ed89401c1b058fa4935d/image.png" />
         <pubDate>2019-04-03 10:14:36 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/347992811</guid>
      </item>
      <item>
         <title></title>
         <author>kas71</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663209</link>
         <description><![CDATA[Q1 (g)(iii) Grid-connected PV system
]]></description>
         <enclosure url="" />
         <pubDate>2019-04-27 11:34:56 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663209</guid>
      </item>
      <item>
         <title></title>
         <author>kas71</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663211</link>
         <description><![CDATA[Q1 (g)(iii) Grid-connected PV system
]]></description>
         <enclosure url="" />
         <pubDate>2019-04-27 11:34:58 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663211</guid>
      </item>
      <item>
         <title></title>
         <author>kas71</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663908</link>
         <description><![CDATA[Q1 (g)(iii) Grid-connected PV system
]]></description>
         <enclosure url="" />
         <pubDate>2019-04-27 11:45:44 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663908</guid>
      </item>
      <item>
         <title></title>
         <author>kas71</author>
         <link>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663911</link>
         <description><![CDATA[Q1 (g)(iii) Grid-connected PV system
]]></description>
         <enclosure url="" />
         <pubDate>2019-04-27 11:45:45 UTC</pubDate>
         <guid>https://padlet.com/charles_sarimuthu/85u1dkj7bu6t/wish/354663911</guid>
      </item>
   </channel>
</rss>
