      <item>
         <title>Kallams DB</title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810236035</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399684671/94b9c73774eda85e4a08a505a5dabac2/20211012_104250.jpg" />
         <pubDate>2021-10-12 09:55:36 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810236035</guid>
      </item>
      <item>
         <title>Appalling SWA</title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810236860</link>
         <description><![CDATA[<div>This SWA cable was not properly terminated, upon taking the shroud off the steel all flared out. Quality over quantity all day long. Dominik a better attempt next time please.&nbsp;<br><br></div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399684668/61e6d4a7e61dadcddcb5d5cea9f4b0c8/A4C38A45_03DB_4B4F_9F9A_30AB9BF4CF9A.jpeg" />
         <pubDate>2021-10-12 09:56:05 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810236860</guid>
      </item>
      <item>
         <title>Exposed copper</title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810240177</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399685859/b857588f7ce346043c19bae5deb99222/20211012_095725.jpg" />
         <pubDate>2021-10-12 09:57:55 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810240177</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810247986</link>
         <description><![CDATA[<div>Damaged CPC</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399694489/e4227019a7406a5f62c28b376163428e/image.jpg" />
         <pubDate>2021-10-12 10:02:26 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810247986</guid>
      </item>
      <item>
         <title>Unsecured conduit </title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810249836</link>
         <description><![CDATA[<div>Great workmanship despite this horrible blunder🤬🤬</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399696015/166a914fd6fec773624d57945e37e6f9/1DDD01EC_48C1_4A79_9245_526655A27F1E.jpeg" />
         <pubDate>2021-10-12 10:03:26 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810249836</guid>
      </item>
      <item>
         <title>Loose terminations and exposed copper </title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810250327</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399685859/4002b6fa5516a7f355e03f8265b18a2d/20211012_104223.jpg" />
         <pubDate>2021-10-12 10:03:43 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810250327</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810251607</link>
         <description><![CDATA[<div>These conductors we’re loose and fell out the terminal. It also shows that the earth insulation has been trapped by the screw. There is also to much outer sheathing in the box.</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399655071/597de7c43bf44b3708bd27ef2bc712a3/6920FED5_F507_4508_86C3_D7FA3501D516.jpeg" />
         <pubDate>2021-10-12 10:04:33 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810251607</guid>
      </item>
      <item>
         <title>Jess smith </title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810253256</link>
         <description><![CDATA[<div>Too much slack on plugs and switches&nbsp;<br>Switch missing cpc running through it </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399695788/a71f948f5b76b025075a8de9791c8dab/image.jpg" />
         <pubDate>2021-10-12 10:05:32 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810253256</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810253494</link>
         <description><![CDATA[<div>Too much copper showing at termination of a switch.</div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399699730/5beaeca63f4586480c999e0316854d9d/8407D0BD_8938_496A_9EF3_466E7C1F12D1.jpeg" />
         <pubDate>2021-10-12 10:05:41 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810253494</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810254182</link>
         <description><![CDATA[<div>Traywork&nbsp;was slightly wonky </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399695442/fee611520de77201b995e99cfa9d7f74/16340331146114870559562118686723.jpg" />
         <pubDate>2021-10-12 10:06:04 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810254182</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810254362</link>
         <description><![CDATA[<div>Bare copper showing at the neutral terminal. </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399700193/cd704f77fb6143ef67751ab12226d6bd/D1F5A780_7293_4979_A47E_B0A511B55F3D.jpeg" />
         <pubDate>2021-10-12 10:06:10 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810254362</guid>
      </item>
      <item>
         <title>Bad termination </title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810255591</link>
         <description><![CDATA[<div>The&nbsp;wire has been been terminated incorrectly, trapping the insulation which is is a potential fire risk. </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399694871/7bca27b0592d32c562de52a7e6ec5f0d/16340331092355905544435740676346.jpg" />
         <pubDate>2021-10-12 10:06:54 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810255591</guid>
      </item>
      <item>
         <title>Ibrahim </title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810255617</link>
         <description><![CDATA[<div>Shroud bit loose<br>Live wire fell out L1 on bottom switch from tug test<br>No twin and earth for sockets, done in 2.5mm singles<br>Lighting circuit done wrong (distribution board went to light first not to switch then light)&nbsp;<br>Finish unfinished tasks<br><br></div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399696111/767423b1bad805e683299cc6467aa91e/IMG_20211012_110138.jpg" />
         <pubDate>2021-10-12 10:06:54 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810255617</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810256429</link>
         <description><![CDATA[<div>Trunking has only been used for some of the wires and not all of them </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399700181/338bef9dff90e9e5ebdd13e3453f3a63/image.jpg" />
         <pubDate>2021-10-12 10:07:23 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810256429</guid>
      </item>
      <item>
         <title>Terminations not doubled over</title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810256497</link>
         <description><![CDATA[<div>In the distribution board the terminations are not doubled over </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399663020/c35cae883ee8e9d738f28a759e2d7ddb/EBDEC556_A31F_43A4_AF19_6C0E59A51421.jpeg" />
         <pubDate>2021-10-12 10:07:26 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810256497</guid>
      </item>
      <item>
         <title>Sharp Edges </title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810258420</link>
         <description><![CDATA[]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399703199/77023c2427aa05b544c699146bae6e26/F6A827D9_84F1_4CA7_9363_CEF2114A0F23.jpeg" />
         <pubDate>2021-10-12 10:08:30 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810258420</guid>
      </item>
      <item>
         <title>Poor termination of conductor </title>
         <author></author>
         <link>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810266193</link>
         <description><![CDATA[<div>This&nbsp;conductor failed the tug test. It was pulled from the MCB in the distribution board and upon inspection I noticed the copper has started to snap off. </div>]]></description>
         <enclosure url="https://padlet-uploads.storage.googleapis.com/1399694871/24c922650aa4d618947169003c919e61/20211012_104811.jpg" />
         <pubDate>2021-10-12 10:12:42 UTC</pubDate>
         <guid>https://padlet.com/HETAElectrical/597esbkm1c4h/wish/1810266193</guid>
      </item>