      <description>1.  THE GROUP ACT AS THE CO/2O.  LISTEN TO THE BRIEFING, DISCUSS AND WRITE DOWN WHAT YOU UNDERSTAND IS THE JOB REQUIREMENT FROM THE TOOLBOX BRIEFING.  2.  TYPE THE GROUP RESPONSE JOB REQUIREMENTS) INTO P9a - USE BULLET POINTS OF THE TOOLBOX BRIEFING. </description>
      <language>en-us</language>
      <pubDate>2020-03-31 14:32:43 UTC</pubDate>
      <lastBuildDate>2025-07-16 09:55:18 UTC</lastBuildDate>
      <webMaster>hello@padlet.com</webMaster>
      <image>
         <url></url>
      </image>
      <item>
         <title>Table 1</title>
         <author></author>
         <link>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521178178</link>
         <description><![CDATA[<p>Task ..change acc gangway wire</p><p><br></p><p>Safety.</p><p>Onsite tool box meeting to be done.</p><p>In sub zero temp..,</p><p>..winter gear to be there and checked and wire handling ppe to be present</p><p>wire handling procedures discussed, </p><p>go thru ra and permit,</p><p> pics before and after job finish, </p><p>wire to be greased during the process and installation time, </p><p>keep harness and life vest ready, if in doubt don't.</p><p>The ladder to be secured with regular and 3 extra lashing</p><p>When changing wire all sheaves and nipples to be cleared,cleaned</p><p>All limits and interlocks to be checked, greased and tried out.</p><p>If in doubt immediately call co.</p><p><br></p><p><br></p>]]></description>
         <enclosure url="" />
         <pubDate>2025-07-16 09:49:56 UTC</pubDate>
         <guid>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521178178</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521178555</link>
         <description><![CDATA[<p>Proceeding towards north sea during winter season temp 0deg </p><p>Beam swell</p><p>4 new joiners - Bosun, Ab &amp; os</p><p>Accommodation ladder wire renewal</p><p>During carrying out the job take 3 additional lashing strong points</p><p>Greasing of all hidden and wire while replacing</p><p>Tool box meeting after renewal of wire and before testing</p><p>Complete testing after renewal</p><p>Before &amp; after completion of job inform bridge</p><p>After completion of renewal and testing securing has be to be done for sea</p>]]></description>
         <enclosure url="" />
         <pubDate>2025-07-16 09:50:55 UTC</pubDate>
         <guid>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521178555</guid>
      </item>
      <item>
         <title>Table 4</title>
         <author></author>
         <link>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521179591</link>
         <description><![CDATA[<p>ACCOMMODATION LADDER RENEWAL</p><ol><li><p>Winter precaution</p></li><li><p>RA and work aloft permit</p></li><li><p>Ensure Familiarisation of new crew and all crew involved</p></li><li><p>Cross verification of spare availability and grease applicable</p></li><li><p>Availablity of winter gear</p></li><li><p>Timely reporting to bridge and ch off</p></li><li><p>Extra lashing atleast 3 to be taken</p></li><li><p>Sub zero condition precaution</p></li><li><p>Checking of limit switch, sheaves and unaccessible parts</p></li><li><p>Familiarise from maker manual about the wire rope specifications</p></li><li><p>After completion of job, inspection and try the equipment for correct operation and prepare closure report</p></li></ol>]]></description>
         <enclosure url="" />
         <pubDate>2025-07-16 09:53:14 UTC</pubDate>
         <guid>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521179591</guid>
      </item>
      <item>
         <title></title>
         <author></author>
         <link>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521180475</link>
         <description><![CDATA[<p>The vessel is in north sea during winters and accomodation ladder needs to be changed</p><p><br/></p><p>Four new joiners bosun 1 ab and 1 os</p><p><br/></p><p>Chief officer instructed bosun to change wire and take before and after photographs of all the sheeves and wires.</p><p><br/></p><p>Correct lowering procedure to be followed and wire to be fully greased prior and during coiling on the drum.</p><p>Tool box meeting needed before the test lowering of the ladder and make sure secured after wards for sea.</p><p>Chief officer asked bosun to risk assessment in pal and use correct ppe for cold weather</p><p>Three more additional lashings to be used along the length of the ladder to strong points</p><p>Weather is zero degrees and beam swells.</p><p>During job all sheeves linit switches and inaccessible areas to be checked and greased</p>]]></description>
         <enclosure url="" />
         <pubDate>2025-07-16 09:55:17 UTC</pubDate>
         <guid>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521180475</guid>
      </item>
      <item>
         <title>Table 3</title>
         <author></author>
         <link>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521180541</link>
         <description><![CDATA[<p>PTW and RA and company approval and master reviewed the RA then </p><p><br/></p><p>Master refuse to give permission as weather is not good , will wait for weather improvement </p>]]></description>
         <enclosure url="" />
         <pubDate>2025-07-16 09:55:24 UTC</pubDate>
         <guid>https://padlet.com/anastasiia_savluk/2cl7pxq36js8/wish/3521180541</guid>